IC-M802 General version
|
| Frequency range | Tx |
1.6–2.9999 MHz 4.0–4.9999 MHz 6.0–6.9999 MHz 8.0–8.9999 MHz 12.0–13.9999 MHz 16.0–17.9999 MHz 18.0–19.9999 MHz 22.0–22.9999 MHz 25.0–27.5000 MHz |
| Rx |
0.5–29.9999 MHz |
| Power supply requirement |
13.6V DC ±15% (negative ground) |
Dimensions (W×H×D) (Projections not included) |
Main unit: 240×94×238.4 mm; 97/16×311/16×93/8 in Controller unit: 220×110×84.4 mm; 821/32×411/32×35/16 in |
| Weight (approx.) |
Main unit: 4.7kg; 10.4lb, Controller unit: 570g; 1.3lb |
| Current drain (approx.) | Transmit (High) |
30A typ. at max. power |
| Max. audio output |
3.0A |
| Sensitivity | J3E, A1A, J2B, F1B (at 10dB S/N; 1.8–29.999MHz) |
0.5μV |
H3E (at 10dB S/N; 1.8–3.999MHz) |
3.2μV |
| Selectivity | J3E, R3E, J2B, A1A |
2.4kHz/–6dB 3.6kHz/–60dB |
| Audio output power (10% dist/ 4Ω load) |
4.0W |
RF output power (PEP) (output power differs depending on version) |
150/60/20W |
|
GENERAL
| |
IC-F61M
|
| Frequency range |
457.525–467.575MHz
|
| Number of operating channels |
9 UHF onboard channels (25kHz channel) |
| Channel spacing |
25kHz |
Current drain (at 7.2V DC) | Tx | 2W ERP output |
1.0A |
| 0.2W ERP output |
0.4A |
| Rx | AF Max. |
500mA (Internal SP) 300mA (External SP) |
| Stand-by |
85mA |
| Operating temp. range |
–20°C to +55°C |
Dimensions (projections not included; W×H×D) |
56×97×36.4 mm |
| Weight (approx.) |
284g (with BP-227) |
TRANSMITTER
| |
IC-F61M
|
| Output power |
2W ERP/0.2W ERP |
| Spurious emissions |
0.25μW |
| Adjacent channel power |
70dB |
RECEIVER
| |
IC-F61M
|
| Sensitivity (at 20dB SINAD) |
–4dBμ typ. emf |
| Adjacent Ch. selectivity |
73dB typ. |
| Spurious response |
70dB |
| Intermodulation rejection |
70dB typ. |
Audio output power (at 5% dist. with an 8Ω load) | Internal speaker |
0.7W typ. |
| External speaker |
0.5W typ. |
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
| Standard | MIL-810 F Method, Proc. |
| Low Pressure Storage |
500.4 I |
| Low Pressure Operation |
500.4 II |
| High Temperature Storage |
501.4 I |
| High Temperature Operation |
501.4 II |
| Low Temperature Storage |
502.4 I |
| Low Temperature Operation |
502.4 II |
| Temperature Shock |
503.4 I |
| Solar Radiation |
505.4 I |
| Rain Blowing |
506.4 I |
| Rain Drip |
506.4 III |
| Humidity Induced |
507.4 |
| Salt Fog |
509.4 |
| Dust Blowing |
510.4 I |
| Vibration |
514.5 I |
| Shock Functional |
516.5 I |
| Shock Transit Drop |
516.5 IV |
Also meets equivalent MIL-STD-810-C, -D and -E.
Ingress Protection Standard
| Dust and Water |